    Using Analytics & IoT to Optimize performance of Diesel generator sets

    Using Analytics & IoT to Optimize performance of Diesel generator sets

    Using Analytics & IoT to Optimize performance of Diesel generator sets

    Using Analytics & IoT to Optimize performance of Diesel generator sets
    AIM Media House··Updated DECEMBER 31, 2024, 5:30 AM
    5 min
    Diesel generator (DG) sets are used by a wide variety of businesses most of the times to provide a backup power source. It comes in varying capacities for various businesses that they serve in such as,  manufacturing, mining, off-shore platforms, offices, and universities.  Usually, a 30 kVA single phase DG set is preferred for a small shop while a 2500 kVA DG set is used for a large factory. The issue here is that unless the DG set is operated at its optimal load (usually 80% of maximum load) the amount of diesel consumed as opposed to energy produced becomes skewed. A sub-optimal load can cause losses up to 75% of revenue. Also, DG sets start performing sub-optimally when regular maintenance is not done. The only way this can be ascertained by the amount of energy being produced, against the diesel consumed.

    Parameters to monitor

    In order to successfully optimize DG set performance, one must monitor a wide variety of parameters. Each of these parameters has its own significance in the optimization of the DG set. Some of the parameters to be monitored are:

    Load

    The load on a DG defines the amount of energy that a DG has to supply. Running a DG on less than optimal load causes carbon buildup on inside the engine. This results in a reduction of power producing the capacity of the DG. Overloading a DG also reduces its efficiency by increasing the wear and tear of the engine and ultimately, reducing the engine’s life.

    Operational hours

    The amount of time for which the DG set has been working is one of the most important parameters to monitor accurately. As DG sets are used for a wide variety of purposes, operational hours help in understanding the usage patterns of the DG.

    Fuel usage

    Fuel has to be closely monitored in order to understand about the overall efficiency of the DG; how the quality of the fuel affects the performance and whether there’s any fuel theft happening. Fuel is directly related to the cost of operating the DG set.

    Coolant, lube oil pressure, engine temperature

    Coolants are used for keeping the engine temperature in check, in order to prevent rusting of the engine. The dip in coolant levels, if not corrected in time, causes the DG to overheat, and may cause irreparable damage to the DG set.

    Battery status

    Batteries in DG sets are used in order to provide starting voltage. The batteries deteriorate over a period of time and lead to problems in starting the DG set.

    How analytics figures in

    Analytics in DG set monitoring helps to reduce incidents of misuse and misapplication. It helps to prevent fuel thefts while allowing maximum uptime. A wide variety of patterns that can be found by using a good monitoring system include:

    Fuel patterns

    Fuel Analysis Fig. 1: Fuel consumed vs operational hours comparison Keeping a track of fuel consumed by the DG set, especially when compared with the energy produced and operational hours, gives a perfect idea of its overall efficiency. Obviously, a DG consuming more fuel, and producing less energy, is in need of maintenance. A comparison of fuel consumed with the energy consumption gives an idea of how the health of DG is over a particular time period. Over the period of time, a pattern of increasing fuel consumption for lesser energy production will be observed. When such a pattern comes up, the DG can be sent for preemptive maintenance, instead of waiting for a breakdown. This helps in increasing the uptime and the overall life of the DG. Fuel vs KWh Fig. 2: Fuel vs KWh over operational hours

    Load patterns

    The load patterns of a DG set help in understanding the usage patterns. A DG that is mostly under-loaded should be replaced with a DG of smaller rating. Conversely, a DG that is overloaded most of the times, should either be replaced by a single higher capacity DG or multiple lower capacity DGs. Load Analysis Fig. 3: Load analysis of DG set Load analysis also helps in case multiple DGs are being operated. For example, in case of load is increasing or decreasing at regular intervals in a day, the operator can choose when to engage a single DG, and when to engage the other DGs.

    Conclusion

    The smart city initiative being launched in 100 cities in India, promises to bring a wealth of data for purposes of analysis and trend finding. DG set monitoring system, will play a big part in understanding the load patterns of industries, oil rigs, townships and gated communities. The system will benefit DG set manufacturers, providers, and users by fetching accurate data of the performance of their DG sets. Analysis of this data will help in making informed business decisions that will enable consumers to cut operational costs, and increase efficiency.

    Your reaction

    Discussion

    What's your take on this story?

    0/1000

    No comments yet — be the first to share your view.

    Explore our newsletters

    Build your routine with some of our top newsletters or view them all here.

    Wake up informed

    Make sense of the day's AI news and breakthroughs with our morning briefing.

    Belamy
    WeeklyBelamySee the latest

    Industry intelligence

    Receive a roundup of AI adoption stories by industry vertical, curated for professionals.

    3x WeeklySector6See the latest

    By signing up, you agree to our Privacy Policy.

    Membership

    Stay ahead with AI insights.

    Unlimited access to premium articles, exclusive analysis, and the stories shaping India's AI economy.

    Subscribe now

    AIM Americas

    1190 Miraloma Way Suite P, Sunnyvale, CA 94085

    AIM India

    1st Floor, Sakti Statesman, Bellandur, Bengaluru – 560103

    © 2026 AIM. All rights reserved.